Pasadores
Quick release pins
F) Chain hoists
All units in a column will be flown from the AX-
V25 rigging grid (bumper), which should be used
with one hoist. The maximum load that can be
flown using the AX-V25 is 250 kg (550 lb) so one
0.25 Ton hoist will be enough.
Safety factors
Each flying point withstands 180 Kg with a 7:1
safety ratio.
The maximum number of variant 25A units that
can be flown from the AX-V25 bumper is 20 units
with a 7:1 safety ratio. The maximum number of
variant 18A/112A units that can be flown from the
AX-V25 bumper are 6 units. Never exceed the
maximum number of units recommended.
2 x180 Kg (7:1)
4 x180 Kg (7:1)
breaking load limit and the maximum
safe working load limit (SWLL). In this case, the
breaking load limit of each of the flying points is
875 kg (1925 lb) as determined by destructive
testing in independent laboratories. With a 7:1
safety factor, a total amount of 20 units variant 25A
can be suspended from the AX-V25.
The safety factor is defined as the coefficient
between the
4 x180 Kg (7:1)
20