Manual del usuario/ User´s manual 40Variant series
4.7 SYSTEM INSTALLATION USING
THE WALL SUPPORT AXW-V25
Then hang the first VARIANT 25A unit from
the wall mount accessory. The two M8x30 DIN965
screws have to be removed from each side of the box
and replaced by two M8x35DIN912 screws.
Up to three VARIANT 25A units can be wall
mountedby means of theAXW-V25accessory.
First the accessory must be fixed to the
wall, making sure in advance that the work load of the
wall allows for it. The wall mount accessory will be
attached to the wall using six nº 10 rawlplugs and six
7x 40 mm screws.
Three different washers must be used along
the M8x35DIN912 screws and placed in thefollowing
order-grower (lock) washer, metal washer and rubber
washer.
Warning!!If three VARIANT25A units have to be hung
it is advisable to fix the box in the middle to the wall
mountaccessory.
M8X30 DIN965
Rubber washer
M8x35 DIN 912
Grower washer
Metal washer
In order to hang the rest of the boxes the
captive rigging hardware and safety pins will be used,
and the procedures described on the 4.3 paragraph of
this manual will be followed. The picture below shows
three VARIANT25A units fixedto the wall.